      Features & Specifications
      Infusion Only Syringe Pumps
      Pump Model
      Standard
      Order #
      Programmable
      Order #
      Number of Syringes
      1
      2
      2 to 10*
      2 to 10*
      2 to 10*
      2 to 10*
      Minimum
      Syringe Size
      0.5 µl
      0.5 µl
      0.5 µl
      0.5 µl
      0.5 µl
      0.5 µl
      Maximum
      Syringe Size
      50/60 ml
      10 ml
      140 ml
      140 ml
      140 ml
      140 ml
      Minimum Flow Rate
      0.0014 µl/hr
      0.0014 µl/hr
      0.002 µl/hr
      0.002 µl/hr
      1.56 pl/min
      0.0001 µl/hr
      Maximum Flow Rate
      26.56 ml/min
      7.91 ml/min
      55.1 ml/min
      55.1 ml/min
      220.97 ml/min
      220.82 ml/min
      Average Linear
      Force (lbs)
      16
      16
      47
      47
      75 (Adjustable)
      50 or 66**
      RS-232
      Computer Control
      No
      No
      Yes
      Yes
      Yes
      Yes
      USB
      Computer Control
      No
      No
      No
      No
      Yes
      No
      TTL Connection
      No
      No
      Yes
      Yes
      Yes
      Yes
      Control Box
      Dimensions
      (H x W x D)
      13 x 22.9 x 11.4 cm
      (5 x 9 x 4.5 in)
      13 x 22.9 x 11.4 cm
      (5 x 9 x 4.5 in)
      28 x 22.2 x 14 cm
      (11 x 8.75 x 5.5 in)
      28 x 22.2 x 14 cm
      (11 x 8.75 x 5.5 in)
      18.4 x 21.6 x 30.5 cm
      (7.25 x 8.5 x 12 in)
      15.9 x 22.8 x 27.9 cm
      (6.3 x 9 x 11 in)
      Pump Head Dimensions
      (H x W x D)
      Weight
      2.1 kg (4.6 lbs)
      2.1 kg (4.6 lbs)
      4.5 kg (10 lbs)
      4.5 kg (10 lbs)
      4.5 kg (10 lbs)
      4.5 kg (10 lbs)
      * Depends upon the Syringe Rack
      ** Available in Standard Force= 50 lbs or High Force= 66 lbs.
       
      Infusion/Withdrawal Syringe Pumps
      Pump Model
      Standard
      Order #
      Programmable
      Order #
      Number of
      Syringes
      1
      2
      2
      1
      2 to 10*
      2
      2 to 10*
      Minimum
      Syringe Size
      0.5 µl
      0.5 µl
      0.5 µl
      0.5 µl
      0.5 µl
      0.5 µl
      0.5 µl
      Maximum
      Syringe Size
      50/60 ml
      10 ml
      10 ml
      1 ml
      140 ml
      140 ml
      140 ml
      Minimum Flow Rate
      0.0014 µl/hr
      0.0014 µl/hr
      1.3 pl/min
      3.3 nl/min
      0.002 µl/hr
      0.0004 µl/hr
      1.56 pl/min
      Maximum Flow Rate
      26.56 ml/min
      7.91 ml/min
      0.4394 ml/min
      1901 µl/min
      55.1 ml/min
      106.6 ml/min
      220.97 ml/min
      Average Linear
      Force (lbs)
      16
      16
      25
      12
      47
      57
      75 (Adjustable)
      RS-232
      Computer Control
      Yes
      Yes
      Yes
      Yes
      Yes
      Yes
      Yes
      USB
      Computer Control
      No
      No
      No
      No
      No
      No
      Yes
      TTL Connection
      No
      No
      Footswitch
      Footswitch
      Yes
      Yes
      Yes
      Control Box
      Dimensions
      (H x W x D)
      13 x 22.9 x 11.4 cm
      (5 x 9 x 4.5 in)
      13 x 22.9 x 11.4 cm
      (5 x 9 x 4.5 in)
      11.4 x 22.9 x 11.4 cm
      (4.5 x 9 x 4.5 in)
      8.9 x 22.9 x 11.4 cm
      (3.5 x 9 x 4.5 in)
      28 x 22.2 x 14 cm
      (11 x 8.75 x 5.5 in)
      15.2 x 31.1 x 28.6 cm
      (6 x 12.5 x 11.25 in)
      18.4 x 21.6 x 30.5 cm
      (7.25 x 8.5 x 12.0 in)
      Pump Head
      Dimensions
      (H x W x D)
      1 x 18.5 x 5 cm
      (2.5 x 7.25 x 2 in)
       
      Weight
      2.1 kg (4.6 lbs)
      2.1 kg (4.6 lbs)
      2.3 kg (5 lbs)
      2.06 kg (4.6 lbs)
      4.5 kg (10 lbs)
      6.8 kg (15 lbs)
      4.5 kg (10 lbs)
      * Depends upon the Syringe Rack
      ** Available in Standard Force= 50 lbs or High Force= 66 lbs.
       
      Infusion/Withdrawal Syringe Pumps (continued)
      Pump Model
      Standard
      Order #
      Programmable
      Order #
      Number of Syringes
      2 to 10*
      2
      4
      4
      1
      2
      Minimum
      Syringe Size
      0.5 µl
      0.5 µl
      20 ml
      20 ml
      2.5 ml
      0.5 µl
      Maximum
      Syringe Size
      140 ml
      140 ml
      200 ml
      200 ml
      100 ml
      140 ml
      Minimum Flow Rate
      0.0001 µl/hr
      0.0001 µl/hr
      1.5 µl/hr
      1.5 µl/hr
      0.0076 µl/min
      0.0004 µl/hr
      Maximum Flow Rate
      220.82 ml/min
      220.82 ml/min
      112 ml/min
      112µl/min
      182.40 ml/min
      106.6 ml/min
      Average Linear
      Force (lbs)
      50 or 66**
      50
      433
      433
      200
      200
      RS-232
      Computer Control
      Yes
      Yes
      Yes
      Yes
      Yes
      Yes
      USB
      Computer Control
      No
      No
      No
      Yes
      No
      Yes
      TTL Connection
      Yes
      Yes
      Yes
      Yes
      Yes
      Yes
      Control Box Dimensions
      (H x W x D)
      15.9 x 22.8 x 27.9 cm
      (6.3 x 9 x 11 in)
      9.5 x 27.9 x 22.9 cm
      (3.75 x 11 x 9 in)
      9.5 x 27.9 x 22.9 cm
       (3.75 x 11 x 9 in)
      9.5 x 27.9 x 22.9 cm
       (3.75 x 11 x 9 in)
      Pump Head Dimensions
      (H x W x D)
      22.9 x 43.2 x 30.5 cm
      (9 x 17 x 12 in)
      22.9 x 43.2 x 30.5 cm
      (9 x 17 x 12 in)
      22.9 x 43.2 x 30.5 cm
      (9 x 17 x 12 in)
      Weight
      4.5 kg (10 lbs)
      13.6 kg (30 lbs)
      18.18 kg (40 lbs)
      18.18 kg (40 lbs)
      6.4 kg (14 lbs)
      6.4 kg (14 lbs)
      * Depends upon the Syringe Rack
      ** Available in Standard Force= 50 lbs or High Force= 66 lbs.
       
      Push/Pull Syringe Pumps
      Pump Model
      Standard
      Order #
      Programmable
      Order #
      Programmable
      Pump Model
      Available
      Available
      Number of Syringes
      4 (2 on each side
      of pusher block)
      4 (2 on each side
      of pusher block)
      Minimum Syringe Size
      0.5 µl
      0.5 µl
      Maximum Syringe Size
      140 ml+
      140 ml+
      Minimum Flow Rate
      0.0001µl/hr
      1.56 pl/hr
      Maximum Flow Rate
      70.518 ml/min
      220.97 ml/min
      Average Linear
      Force (lbs)
      50 or 60**
      75 (Adjustable)
      RS-232 Computer Control
      Yes
      Yes
      USB Computer Control
      No
      Yes
      TTL Connection
      Yes
      Yes
      Control Box Dimensions
      (H x W x D)
      15.9 x 22.8 x 27.9 cm
      (6.3 x 9 x 11 in)
      18.4 x 21.6 x 30.5 cm
      (7.25 x 8.5 x 12.0 in)
      Pump Head Dimensions
      (H x W x D)
      Weight
      4.5 kg (10 lbs)
      4.5 kg (10 lbs)
       
      Syringe Pump Application Guide
       
      Accurate Delivery of Coatings
       
       
       
       
       
       
       
       
       
       
      Animal Feeding
       
       
       
       
       
       
       
       
       
      Biomedical Dispensers
       
       
       
       
       
       
       
       
       
       
       
      Bulk Fluid Transfer
       
       
       
       
       
       
       
       
       
       
       
      Cell Cultures
       
       
       
       
       
       
       
       
       
       
       
      Cellular Injection
       
       
       
       
       
       
       
       
      Continuous Infusions
       
       
       
       
       
       
       
       
       
       
       
      Doping
       
       
       
       
       
       
       
       
       
      Drug Delivery (same infusion rates)
       
       
       
       
       
       
       
       
       
      Drug Delivery
      (different infusion rates)

      (RS232)*
       
       
       
       
       

      (RS232)*

      (USB)*
       
       
      Drug Delivery (time released)
       
       
       
       
       
       
       
       
       
      Drug Development
       
       
       
       
       
       
       
       
       
       
       
      Electrospinning
       
       
       
       
       
       
       
       
       
      Fluid Blending

      (RS232)*
       
       
       

      (RS232)*
       
       
       
      Fluid Blending
      (2 independent channels)
       
       
       
       
       
       
       
       
       
       
       
      Fluid Sampling
       
       
       
       
       
       
      Gradients

      (RS232)*
       
       

      (RS232)*
       

      (RS232)*
      or USB**

      (RS232)*
       
       
       
       
       
      High Pressure Injection
       
       
       
       
       
       
       
      Highly Corrosive Fluids
       
       
       
       
       
       
       
       
      HPLC
       
       
       
       
       
       
       
       
      Injecting Into High
      Pressure Reaction Vessels
       
       
       
       
       
       
       
      Injection Pressure Calculations
       
       
       
       
       
       
       
       
       
      Instrument Injections
       
       
       
       
       
       
       
       
       
      Low Pressure Chromatography
       
       
       
       
       
       
       
       
       
       
      Mass Spectometry
       
       
       
       
       
       
       
       
      Medical Coating Delivery
       
       
       
       
       
       
       
       
       
       
       
       
      Microdialysis
       
       
       
       
       
       
       
       
      MRI Studies
       
       
       
       
       
       
       
       
       
       
       
      Multiple Simultaneous
      Feeding Stations

      (RS232)*
      or USB**
       
       
       

      (RS232)*

      (RS232)*
       
       
       
       
       
       
      Nano Fluidics
       
       
       
       
       
       
       
       
       
       
      Nutritional Studies
       
       
       
       
       
       
       
       
      OEM Modules
       
       
       
       
       
       
       
       
       
       
       
       
       
      Oocyte Applications
       
       
       
       
       
       
       
       
       
       
      Patch Clamping
       
       
       
       
       
       
       
       
       
       
       
      Remote Pumping
      of Hazardous Material
       
       
       
       
       
       
      Stereotaxic Devices
       
       
       
       
       
       
       
       
       
       
       
      Titrations

      (RS232)*
       
       

      (RS232)*
       
       
       
       
       
       
       
      Viscous Solutions
       
       
       
       
       
       
       
      * Can be done using RS232 or USB computer control.